27. Product in Position (LS1 Close) Start button on. Conveyer moves product to A (Limit switch LS1 returns to normal) Conveyer moves the Product to A and stops Distance to A counted by encoder (8 Pulses) Waits at A for 10 s Moves again to LS2 and stops Emergency stop Emergency stop resets counter and timer