Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
osama 
warda 
2
osama 
warda 
3
osama 
warda 
4
osama 
warda 
5
Double 
valve 
syringe 
osama 
warda 
6
Single 
Valve 
Aspirator 
Product 
Code: 
SVSS10 
(sterile 
pack 
of 
10) 
! For 
uterine 
evacuation 
and 
endometrial 
b...
In 
the 
old 
fashion 
cannulae, 
the 
adaptors 
were 
provided 
separate 
osama 
warda 
8
The 
Ipas 
easy 
grip 
cannula: 
-­‐Yellow= 
4mm 
-­‐light 
Green 
5mm 
-­‐Blue=6mm 
-­‐Brown=7mm 
-­‐White=8mm 
-­‐Tan=9m...
osama 
warda 
10
osama 
warda 
11
osama 
warda 
12
osama 
warda 
13
osama 
warda 
14
osama 
warda 
15
osama 
warda 
16
osama 
warda 
17 
The 
size 
of 
cannula 
is 
roughly 
the 
number 
of 
gestational 
weeks 
i.e. 
7wks= 
7mm 
cannula
osama 
warda 
18
osama 
warda 
19
osama 
warda 
20
osama 
warda 
21
Reuse 
of 
the 
instrument: 
• The Ipas MVA Plus® is a multiple-use device that requires 
high-level disinfection or steri...
osama 
warda 
23
Thank 
you 
osama 
warda 
24
MANUAL VACUUM ASPIRATION
You’ve finished this document.
Download and read it offline.
Upcoming SlideShare
Manual vacuum aspirator
Next
Upcoming SlideShare
Manual vacuum aspirator
Next
Download to read offline and view in fullscreen.

Share

MANUAL VACUUM ASPIRATION

Download to read offline

The MVA is a safe method to perform abortion (incomplete abortion, and office endometrial biopsy

Related Books

Free with a 30 day trial from Scribd

See all

MANUAL VACUUM ASPIRATION

  1. 1. osama warda 2
  2. 2. osama warda 3
  3. 3. osama warda 4
  4. 4. osama warda 5
  5. 5. Double valve syringe osama warda 6
  6. 6. Single Valve Aspirator Product Code: SVSS10 (sterile pack of 10) ! For uterine evacuation and endometrial biopsy ! Individually wrapped and disposable ! Ready to use and sterilely packed ! Accepts 3, 4, 5, and 6 mm diameter cannulae osama warda 7
  7. 7. In the old fashion cannulae, the adaptors were provided separate osama warda 8
  8. 8. The Ipas easy grip cannula: -­‐Yellow= 4mm -­‐light Green 5mm -­‐Blue=6mm -­‐Brown=7mm -­‐White=8mm -­‐Tan=9mm -­‐Dark Green =10mm -­‐No 11 mm cannula -­‐12 mm cannula needs no adaptor osama warda 9
  9. 9. osama warda 10
  10. 10. osama warda 11
  11. 11. osama warda 12
  12. 12. osama warda 13
  13. 13. osama warda 14
  14. 14. osama warda 15
  15. 15. osama warda 16
  16. 16. osama warda 17 The size of cannula is roughly the number of gestational weeks i.e. 7wks= 7mm cannula
  17. 17. osama warda 18
  18. 18. osama warda 19
  19. 19. osama warda 20
  20. 20. osama warda 21
  21. 21. Reuse of the instrument: • The Ipas MVA Plus® is a multiple-use device that requires high-level disinfection or sterilization prior to initial use and between patients. • The aspirator does not need to be high- level disinfected or sterile at the time of use. • Cannulae must be high-level disinfected or sterile at the time of use.Ipas EasyGrip® cannulae are sterilized with ethylene oxide after packaging and remain sterile until the stated expiration date, as long as the package is intact. Where regulations allow, Ipas EasyGrip® cannulae are multiple-use devices. osama warda 22
  22. 22. osama warda 23
  23. 23. Thank you osama warda 24
  • VictorIferika

    Oct. 3, 2021
  • NaandaPablo

    Sep. 18, 2021
  • InnocentMumbi

    Sep. 15, 2021
  • PoojaPhadtare1

    Aug. 24, 2021
  • KelvinRobin

    Aug. 2, 2021
  • YasminKabir1

    Aug. 1, 2021
  • Savitrkatti

    Jul. 16, 2021
  • MisbaahShaikh

    Jun. 30, 2021
  • ADRIANOLUBANGA

    Jun. 27, 2021
  • SamuelThankgod

    Jun. 23, 2021
  • HarpreetKaur551

    Jun. 2, 2021
  • OnenchanInnocent

    May. 26, 2021
  • JosefAmeh

    May. 20, 2021
  • ChukwuEmmanuel2

    May. 13, 2021
  • cyrusnyabuto

    Apr. 29, 2021
  • IbraheemAttahir

    Apr. 23, 2021
  • SPIDERshadow

    Apr. 21, 2021
  • AmonlaphaZhou

    Apr. 17, 2021
  • ShubhiGupta90

    Apr. 5, 2021
  • AbdulrahmanSalawudee

    Feb. 20, 2021

The MVA is a safe method to perform abortion (incomplete abortion, and office endometrial biopsy

Views

Total views

31,322

On Slideshare

0

From embeds

0

Number of embeds

32

Actions

Downloads

884

Shares

0

Comments

0

Likes

100

×